Exhaust Fan Sizes: What 4, 6, 8, 10, 12 and 18 Inch Actually Deliver

The inch on the box is a mounting size, not a performance figure. In our own range a 6 inch fan moves anywhere from 150 to 1,670 m³/h depending on type — eleven times the airflow at the same nominal size. This page gives the airflow, room coverage and wall cut-out behind every size we make, so you order by the number that matters instead of the one on the carton.

Last updated: November 3, 2026

Home / Products / Exhaust Fan Sizes Guide

Two buyers order a “6 inch exhaust fan” and receive two completely different machines: one shifts 150 m³/h out of a bathroom, the other shifts 1,670 m³/h out of a workshop. Both are honestly described as 6 inch. This guide explains what the size refers to on each fan type, how much air each size can realistically move, and what hole you have to cut in the wall — the three things that decide whether the fan works in your space.

THE BASICS

The Inch Is a Mounting Size, Not an Airflow

On a bathroom or panel fan, the inch refers to the nominal fan diameter inside a square wall panel — a 6 inch panel fan has a 200×200 mm faceplate. On a duct fan, the industry quotes the duct diameter in millimetres instead (100/125/150/200/250/315 mm). On a high-airflow wall shutter fan, the inch describes the blade and housing, and the same nominal size can be built with a much deeper blade and a faster motor. Airflow is set by blade design, motor speed and static pressure — never by the inch alone.

Fan type4″ (100 mm)6″ (150 mm)8″ (200 mm)10″ (250 mm)12″ (300 mm)18″ (450 mm)
Bathroom fan (quiet)50–100 m³/h100–220 m³/h————
Panel fan (KLT)—150 m³/h380 m³/h432 m³/h792 m³/h1,800 m³/h
Duct fan (BXF)290 m³/h620 m³/h1,200 m³/h1,800 m³/h2,200 m³/h (315 mm)—
High-airflow wall shutter—1,670 m³/h (984 CFM)————

Rated free-air figures. Read the row, not the column: at 6 inch the spread is 150–1,670 m³/h, and the fan you need depends on the room, the mounting and the pressure — not on the nominal size.

ROOM COVERAGE

Which Size for Which Room

Bathroom up to 5 m²

About 10 m³ of air at 8–10 changes per hour: 80–100 m³/h. A 4 inch (100 mm) quiet bathroom fan is enough — going bigger mainly buys noise.

Bathroom 6–10 m²

150–200 m³/h. 6 inch bathroom fan, or a KLT-10B panel fan if the wall is masonry and you want a shutter louvre.

Kitchen 10–15 m² (domestic)

12–15 air changes: 400–550 m³/h. 8 inch panel fan (KLT-12B, 380 m³/h) as a minimum; use the ducted BXF-150 (620 m³/h) if the fan cannot sit on an outside wall.

Living room / bedroom 20–30 m²

6–8 air changes: 350–600 m³/h. 8 inch panel fan or a silent cabinet fan where noise matters more than volume.

Small office / shop 40–60 m²

650–900 m³/h. 12 inch panel fan (KLT-20B, 792 m³/h) or two smaller units on opposite walls.

Workshop / warehouse 60–100 m²

8–12 air changes: 1,800–3,000 m³/h. 18 inch panel fan (KLT-30B) or two 14 inch units (KLT-25B, 1,500 m³/h each).

THE CALCULATION

Size by Air Changes, Not by Guesswork

Every size decision reduces to one sum: room volume × air changes per hour = airflow needed. Volume is length × width × ceiling height, not floor area — the single most common mistake. Air change rates by room type:

RoomAir changes per hourNotes
Bathroom / WC8–10Higher if there is no window
Domestic kitchen12–1515–20 if frying regularly
Living room / bedroom6–8Comfort, not moisture control
Office / shop6–8Add for occupancy above one person per 10 m²
Workshop / warehouse8–1212–15 where there is welding or solvent
Dishwash / laundry15–20Moisture-driven; use a ducted fan

Worked example: a kitchen 4 × 3 m with a 2.9 m ceiling is 34.8 m³. At 15 air changes that is 522 m³/h — between the 8 inch panel fan (380) and the 6 inch duct fan (620). Take the larger of the two if the fan is ducted or the room has a window that stays shut. Conversions: 1 m³/h = 0.589 CFM; multiply m³/h by 0.59, or divide CFM by 0.59.

MEASURING

Measure the Opening, Not the Old Fan

Three dimensions decide whether a replacement fits, and only one of them is the size printed on the box. The panel is the visible faceplate that covers the wall. The cut-out is the hole you actually make. The outlet is the spigot diameter, which matters if a duct connects to it.

ModelNominal sizePanel (mm)Wall cut-out (mm)Outlet (Φ mm)Airflow (m³/h)Noise (dB)Coverage
KLT-10B6″200×200160×16085150355–8 m²
KLT-12B8″250×250205×2051003803812–15 m²
KLT-18B10″310×310245×2451004324214–18 m²
KLT-20B12″340×340290×2901007924526–32 m²
KLT-25B14″400×400330×3301501,5004850–60 m²
KLT-30B18″600×600480×4801501,8004860–72 m²

Coverage assumes a 2.7–3.0 m ceiling at 8–10 air changes. Note that the KLT-10B is called 6 inch but needs a 160×160 mm hole — the panel covers the rest. Send a photo of the opening with a tape measure across it and we will confirm the model before you cut anything.

SAME SIZE, THREE FANS

Why One 6 Inch Fan Moves 150 m³/h and Another 1,670

Bathroom fan — 4″ to 6″

Quiet, low power, short duct. Built to shift 50–220 m³/h with an internal backdraught flap for a duct of 100–150 mm. The right choice when the limit is noise, not airflow.

Panel fan (KLT) — 6″ to 18″

Square wall fan with an automatic shutter louvre. Same nominal size, several times the airflow because the blade is deeper and the motor is bigger: 150 m³/h at 6 inch, 1,800 m³/h at 18 inch.

Duct fan (BXF) — 100 to 315 mm

Mixed-flow impeller for pressure, not just volume: 290–2,200 m³/h and up to 693 Pa. Choose it when the fan sits away from the wall or the run has bends.

High-airflow wall shutter — one size, one job

Our 6 inch industrial shutter fan is built for workshops: 984 CFM / 1,670 m³/h at up to 180 Pa. Same 6 inch label, industrial blade and motor.

RULES OF THUMB

Five Things Buyers Get Wrong on Size

1. Using floor area instead of volume. A 3 m ceiling holds 20% more air than a 2.5 m one. Multiply by height, always.

2. Buying one size up instead of fixing the duct. A fan with a long, narrow duct loses more airflow than the next size up would gain. 100 mm duct above 290 m³/h runs at 10 m/s and turns airflow into noise.

3. Forgetting make-up air. Every cubic metre out needs a way back in. A sealed room with a 1,000 m³/h fan can lose a third of that airflow and pull combustion gases down the flue.

4. Oversizing a bathroom. Above about 10 air changes you get a draught across the room, more noise, and a fan that pulls against the door seal. Match the size to the volume.

5. Ordering by inch across borders. A 6 inch fan is 150 mm in a duct, 200×200 mm on a panel and 152 mm on a US spec sheet. Quote both the inch size and the cut-out when you compare suppliers.

RELATED

Specifications & Further Reading

KLT Panel Series — All Six Sizes

BXF Duct Fans — 100 to 315 mm

Silent Bathroom Fans

Window Exhaust Fans (no wall cutting)

Bathroom Airflow: How Much You Need

Airflow Calculator

Commercial Kitchen Exhaust

Industrial Exhaust Fans

Certifications & Factory

CE is standard — certificate XH2601E0321945GC (Xihua International Testing & Certification, Shenzhen), valid to 2031-01-28. The factory holds ISO 9001 (04625Q15304R1M) and CCC (2024010702612682, covering KLT-10B to 18B at 220V/50Hz). ETL can be arranged on request; SAA is renewed per order. All numbers are published for you to verify on the certificate verification page.

BUYER FAQ

Frequently Asked Questions

What size exhaust fan do I need for a 10 m² bathroom? +
A 10 m² bathroom with a 2.6 m ceiling holds 26 m³. At 8–10 air changes that is 210–260 m³/h, so a 6 inch (150 mm) bathroom fan rated around 220 m³/h. If there is no window, take the higher figure. A 4 inch fan is right for a small WC of 3–5 m², not for a family bathroom.
Is a bigger fan always better? +
No. Oversizing causes a draught across the room, more noise, and in a sealed room it starves itself of make-up air so the extra capacity is never delivered. Size to the air-change rate and, where the load varies, use a two-speed or speed-controlled fan instead of a larger one.
My wall opening is 160×160 mm — which fan fits? +
That is the KLT-10B cut-out. Its 200×200 mm panel covers the opening and its 85 mm spigot takes a 100 mm duct — 150 m³/h, 35 dB. If you need more airflow through the same wall, keep the hole and use the BXF-100 duct fan in the run instead, at 290 m³/h.
Why is a 6 inch fan sometimes 150 m³/h and sometimes 1,670? +
Because the inch describes the mounting or blade diameter, not the motor or the blade depth. A 6 inch bathroom fan has a small backward-curved impeller and a low-power motor; our 6 inch industrial shutter fan has a deep axial blade and a much larger motor. Compare airflow at a stated static pressure, not the inch.
How do inches compare to the millimetres on duct fans? +
4″ = 100 mm, 6″ = 150 mm, 8″ = 200 mm, 10″ = 250 mm, 12″ = 300 mm, 14″ = 350 mm, 16″ = 400 mm, 18″ = 450 mm. Duct fans are quoted by duct diameter, so a 150 mm BXF is the “6 inch” one — but it delivers 620 m³/h, four times a 6 inch bathroom fan.
Can I fit a ducted fan if I only have a 100 mm hole? +
Yes — the BXF-100 is 290 m³/h at up to 150 Pa, but 100 mm duct runs at about 10 m/s at that airflow, so keep the run under 3–4 m with no more than two bends. Longer runs need a 150 mm duct and a reducer at the wall.
What if the wall cannot be cut at all? +
Use a window fan: the KLT-W window series covers 468–984 m³/h and mounts in the frame or a replacement glass panel, with the same shutter louvre. It is the usual answer for rented premises and heritage buildings.
Do sizes change for 60Hz or 110V? +
The physical size and cut-out stay the same; the airflow changes. A 60Hz motor runs about 20% faster, so the same fan moves proportionally more air and makes more noise. Quote the voltage with the size so the performance figures we send match what you will install.

Send the Room Size and the Opening

Tell us the room dimensions, the ceiling height, what the space is used for, and the wall or window opening you have. We reply with the airflow you need, the size and model that meets it, and a formal quote — within 24 hours.