An inline duct fan is a fan mounted inside a duct run — pick an axial booster for short, straight, low-pressure ducts, a mixed-flow inline for most ducted runs, and a centrifugal inline for long or complex ducts with high static pressure. BAER (Zhejiang BAER Electrical Technology Co., Ltd.) manufactures all three types at its Zhejiang factory — CE, CB and ISO 9001 certified since 2003, MOQ 100 pcs, samples in 3–7 days.
How inline duct fans work, how to size one, and where each type performs best — factory-direct from BAER.
Last updated: September 14, 2026
An inline duct fan is a fan mounted inside a duct run, so air enters and leaves along a straight line. Unlike a wall or window fan, it can be hidden in a ceiling void or along a duct, and — in its mixed-flow form — it holds its airflow against the pressure of long ducts, bends and grilles. This guide explains the types, how to size one, and where each works best.
Quick answer: Choose an axial booster for a short, straight, low-pressure duct; choose a mixed-flow inline fan for most ducted runs; and choose a centrifugal inline fan when static pressure is high or the duct run is long and complex. Start with the airflow calculation guide to size the room airflow before selecting the fan type.
An inline duct fan sits inside the duct, so air flows straight through it. The motor drives an impeller — propeller (axial), hybrid (mixed-flow) or backward-curved (centrifugal) — that accelerates air along the duct. Because the fan body is inside the duct, the duct itself absorbs most of the sound, which is why inline fans are the quiet choice for bedrooms and offices. The trade-off is that the fan must overcome the duct's static pressure; a weak axial booster will simply stall under resistance while a mixed-flow or centrifugal unit keeps moving air. Our inline vs axial guide shows the trade-offs in detail.
| Type | Impeller | Best for |
|---|---|---|
| Axial booster (duct fan) | Propeller | Short, straight ducts; low pressure |
| Mixed-flow inline | Hybrid axial/centrifugal | Most ducted runs — balanced CFM and pressure |
| Centrifugal inline | Backward-curved | High static pressure, long or complex ducts |
For most residential and commercial ducted ventilation, a mixed-flow inline fan is the sweet spot — it moves air quietly while holding airflow through a typical duct run. See the full comparison in our inline duct fan vs axial fan guide.
Sizing has three steps:
Worked example: A villa bathroom of 3.5 m × 3 m × 2.7 m = 28.4 m³ at 8 ACH needs 227 m³/h (134 CFM). With a 4 m duct and two bends, add 20% → about 270 m³/h (160 CFM). Choose a mixed-flow inline fan rated above that at the expected static pressure.
Static pressure (Pa) is the resistance in the duct from its length, bends, grilles and filters. A booster axial fan is cheap but collapses past a few Pa; a mixed-flow fan holds airflow to ~30–50 Pa; a centrifugal unit goes higher. Our EC vs AC motor guide covers how motor type affects efficiency under variable pressure, and our airflow calculation guide walks through a full duct-pressure budget.
Inline fans are quieter than wall or window fans partly because the duct muffles them and partly because mixed-flow impellers are designed for low turbulence. Expect roughly 25–35 dBA for residential units and slightly more for high-pressure commercial models. Match the duct diameter to the fan and use rigid duct to keep levels down. Our noise levels guide translates dBA into real-world expectations, and our vs axial guide shows why inline wins on noise.
The duct is half the system, and getting it wrong wastes a good fan. Follow four rules. Keep it short and straight — every metre of duct and every 90° bend costs you airflow and adds noise; route the fan as close to the outlet as practical. Match diameters — the duct bore should equal the fan spigot; a step-down creates a pressure spike and whistling. Use rigid or semi-rigid duct over flexi-foil, which ripples internally and roughly doubles resistance. Insulate ducts that pass through unconditioned spaces so condensation does not drip and the air stays at temperature. For a typical villa bathroom a 100–125 mm (4–5 inch) rigid run of under 5 m performs best, and you should size the fan from the duct's actual resistance, not just the room volume — a long, complex run needs a higher-Pa unit than the free-air CFM alone suggests.
BAER manufactures a mixed-flow inline duct fan and a silent cabinet fan, both CE certified with a 2-year warranty. Both are chosen by duct diameter first, then by the airflow your room calculation demands — the table below lists the published range for each, so you can narrow the shortlist before requesting a quote:
| Model | Duct size | Airflow | Static pressure | Noise | Best for |
|---|---|---|---|---|---|
| Inline mixed-flow duct fan | 100 / 125 / 150 / 200 / 250 / 315 mm | 290–2,200 m³/h (171–1,295 CFM) |
Up to 693 Pa | 28–70 dB(A) | Ducted extraction in bathrooms, kitchens and long runs |
| Silent cabinet fan | 100 / 125 / 150 mm | 80–450 m³/h (47–265 CFM) |
On request | ≤ 18 dB(A) | Enclosed, noise-sensitive commercial spaces |
Fan curves are published for the mixed-flow inline series; ask us for the cabinet-fan curve if your duct run is long. Pricing moves with voltage, motor type and order quantity — the exhaust fan price breakdown explains what drives the number, and the EC vs AC motor guide covers the motor choice.
The mixed-flow inline series is built in six duct diameters. Match the model to the airflow your room calculation demands, then confirm the voltage for the destination market — the same fan is available on 220–240V/50Hz and 220V/60Hz platforms.
| Model | Duct size | Airflow (m³/h) | Airflow (CFM) | Static pressure | Speed | Power | Noise |
|---|---|---|---|---|---|---|---|
| BXF-100 | Φ100 mm | 290 | 171 | 150 Pa | 2,750 r/min | 48 W | 28–31 dB(A) |
| BXF-125 | Φ125 mm | 420 | 247 | 180 Pa | 2,650 r/min | 50 W | 28–31 dB(A) |
| BXF-150 | Φ150 mm | 620 | 365 | 300 Pa | 2,450 r/min | 60 W | 28–32 dB(A) |
| BXF-200 | Φ200 mm | 1,200 | 706 | 380 Pa | 2,100 r/min | 120 W | 45–50 dB(A) |
| BXF-250 | Φ250 mm | 1,800 | 1,060 | 488 Pa | 2,000 r/min | 200 W | 54–60 dB(A) |
| BXF-315 | Φ315 mm | 2,200 | 1,295 | 693 Pa | 1,650 r/min | 330 W | 60–70 dB(A) |
Airflow figures are the maximum rating at the stated speed. For a ducted run, size against the static pressure column rather than the free-air figure alone — the CFM calculator shows the margin to add. Export carton data (pcs/ctn, CBM, gross weight) is on the mixed-flow inline duct fan product page, together with the full datasheet, fan curves and speed-control options.
If a wall or panel opening is the only route out, a through-wall fan removes the duct resistance entirely and delivers closer to its rated airflow. These BAER ranges cover that case:
| Model | Opening size | Airflow | Noise | Best for |
|---|---|---|---|---|
| Window mount exhaust fan | 150 / 200 / 250 mm | 120–450 m³/h (71–265 CFM) |
≤ 38 dB(A) | Kitchens and workshops with a direct wall or window route |
| Ceiling mount exhaust fan | 100 / 150 / 200 mm | 80–350 m³/h (47–206 CFM) |
≤ 26 dB(A) | Short duct runs where quiet operation matters more than pressure |
| KLT panel exhaust fan series | 200 × 200 to 600 × 600 mm panel | 150–1,800 m³/h | See the noise guide | Through-panel extraction with auto shutter — the volume workhorse for wall openings |
Once you have a shortlist, the commercial terms sit in the MOQ guide, the container loading guide and the OEM spec sheet. Send us the room dimensions and duct layout and our engineers will return the calculation with a recommended model.
In Saudi Arabia, the UAE, Iraq, Kuwait, Qatar, Oman and Yemen, inline duct fans serve villas, hotels and offices where quiet centralised extraction matters. BAER supplies 220V/60Hz and 220–240V/50Hz motors, dust-resistant bearings and coastal-grade coatings. For long villa duct runs we recommend mixed-flow inline fans sized with margin for heat and filter resistance. See our Middle East overview, the climate guide, or country pages for the Saudi Arabia, UAE, Iraq, Kuwait, Qatar, Oman and Yemen.
Inline duct fans run for thousands of hours a year, so the motor choice drives most of the lifetime cost. A standard AC motor is cheap and robust and suits intermittent residential use. An EC (electronically commutated) motor integrates the controller into the motor, runs cooler and modulates speed efficiently, typically cutting energy use by 30–60% at part load — the payback is fastest in 24/7 commercial extraction, plant rooms and hotel corridors. For villas that run a fan for several hours a day, EC pays back within a couple of years. Pair any EC or multi-speed AC unit with a thermostat or humidity sensor so it only runs when needed — the single biggest saving after the motor itself. In hot climates like the Gulf, a more efficient motor also means less waste heat dumped into the very space you are trying to ventilate, a compounding benefit during summer peaks. For projects specifying many units, ask BAER for the EC option on the quote; our EC vs AC motor guide works through the numbers for your duty cycle.
An inline duct fan mounts inside the duct and, in mixed-flow form, holds airflow against duct pressure. An axial fan moves more air at low pressure but collapses under duct resistance — fine for a short wall pass-through, poor for a long duct run.
Calculate the required CFM from room volume and air changes per hour, add 10–20% margin for duct resistance, and match the fan diameter to the duct diameter. Our CFM calculator does the maths instantly.
Yes. Mixed-flow inline fans are generally quieter than axial fans because the duct absorbs sound and the impeller is designed for lower turbulence. Expect around 25–35 dBA for residential units.
Yes. An inline duct fan is the correct choice when bathroom extraction runs through a ceiling duct rather than a direct wall opening — common in villas and apartments.
Six duct diameters, from BXF-100 (100 mm, 290 m³/h) to BXF-315 (315 mm, 2,200 m³/h). The intermediate models are BXF-125 (420 m³/h), BXF-150 (620 m³/h), BXF-200 (1,200 m³/h) and BXF-250 (1,800 m³/h). Static pressure rises with the model, up to 693 Pa on the BXF-315, which is what lets the larger sizes hold airflow through long or complex duct runs.
Send your application, room size, voltage and quantity — our engineers reply with a recommendation and factory-direct quote within one working day.
Request a Quote